Section Saf-C 1613.01 - Structure
(a) A Type 4 storage facility may be a building, an igloo, a tunnel, a dugout, a box, a trailer, or a semi-trailer or other mobile facility and shall be fire-resistant, weather-resistant, and theft-resistant.
(b) A Type 4 storage facility shall be constructed of masonry, metal-covered wood, fabricated metal, or a combination of these materials. The walls and floors of such storage facilities shall be lined with a non-sparking material. No sparking metal construction shall be exposed below the top of walls in the interior of storage facilities, and all nails therein shall be blind-nailed or counter-sunk.
(c) Foundations shall be constructed of brick, concrete, cement block, stone, or wood posts. If piers or posts are used in lieu of a continuous foundation, the space under the facility shall be enclosed with metal.