N.H. Admin. Code § Saf-C 1610.11

Current through Register No. 36, September 5, 2024
Section Saf-C 1610.11 - Igloos, Tunnels, and Dugouts
(a) Igloos, tunnels, and dugout storage facilities shall be constructed of reinforced concrete, masonry, metal or a combination of these materials. They shall have an earthmound covering of not less than 24 inches on the top, sides and rear.
(b) Interior walls and floors shall be covered with a non-sparking material.
(c) Storage facilities of this type shall also be constructed in conformity with the requirements for buildings in reference to:
(1) Floors, Saf-C 1610.03;
(2) Doors, Saf-C 1610.07;
(3) Locks, Saf-C 1610.08;
(4) Ventilation, Saf-C 1610.09; and
(5) Exposed metals, Saf-C 1610.10.

N.H. Admin. Code § Saf-C 1610.11

#2220, eff 12-31-82; ss by #2837, eff 8-27-84; ss by #4584, eff 3-3-89; ss by #5996, INTERIM, eff 3-3-95, EXPIRES, 7-1-95; ss by #6054, eff 7-1-95, EXPIRED: 7-1-03

New. #8116, INTERIM, eff 7-14-04, EXPIRES: 1-10-05; ss by #8231, eff 12-20-04

Amended by Volume XXXIII Number 37, Filed September 12, 2013, Proposed by #10396, Effective 8/15/2013, Expires 8/15/2023.