Section He-P 4095.01 - Assigned Protection Factors for Respirators

Assigned protection factors for respirators for use by licensees shall be in accordance with Table 4095.1 below:

Table 4095.1 Assigned Protection Factors (APF) for Respirators

Operating Mode Assigned Protection Factors
I. Air purifying respirators (Particulate only) Filtering faceplate disposableu ---------------- Facepiece, halfv---------------------------------- Facepiece, full----------------------------------- Facepiece, half----------------------------------- Facepiece, full----------------------------------- Helmet/hood------------------------------------- Facepiece, loosefitting-------------------------- Negative Pressure------------------- Negative Pressure------------------- Negative Pressure------------------- Powered air-purifying respirators- Powered air- purifying respirators- Powered air- purifying respirators- Powered air- purifying respirators- ( 1u ) 10 100 50 1000 1000 25
II. Atmosphere supplying respirators (Particulate, gases, and vaporsw) 1: Air-line respirator: Facepiece, half-------------------------------- Facepiece, half------------------------------- Facepiece, half-------------------------------- Facepiece, full-------------------------------- Facepiece, full--------------------------------- Facepiece, full--------------------------------- Helmet/hood----------------------------------- Facepiece, loosefitting------------------------ Suit---------------------------------------------- 2: Self-contained breathing apparatus (SCBA): Facepiece, full--------------------------------- Facepiece, full--------------------------------- Facepiece, full--------------------------------- Facepiece, full----------------------------- Demand------------------------------ Continuous Flow-------------------- Pressure Demand-------------------- Demand------------------------------ Continuous Flow-------------------- Pressure Demand-------------------- Continuous Flow-------------------- Continuous Flow-------------------- Continuous Flow-------------------- Demand------------------------------ Pressure Demand------------------- Demand, recirculating------------- Positive Pressure Recirculating--- 10 50 50 100 1000 1000 1000 25 ( 1x ) y100 z10,000 y100 z10,000
III. Combination respirators: Any combination of air-purifying and atmosphere-supplying respirators Assigned protection factor for type and mode of operations as listed above

N.H. Admin. Code § He-P 4095.01

#8393, eff 7-23-05; ss by #10492, eff 12-24-13