Rule 15-16-1-1.47.28 - Required Fire Exits
1. At least two (2) exits, remote from each other, shall be provided for each occupied story of the building. Dead-end corridors are undesirable and in not even shall exceed thirty (30) feet.
2. Exits shall be of such number and so located that the distance of travel from the door of any occupied room to an exit from that floor shall not exceed one hundred (100) feet. In buildings completely protected by a standard automatic sprinkler system, the distance may be one hundred fifty (150) feet.
3. Each occupied room shall have at least one (1) door opening directly to the outside or to a corridor, stairway, or ramp leading directly to the outside.
4. Doors on fire exits shall open to the outside.
5. The current edition of NFPA 101 Life Safety Code (recognized by licensing agency) shall be the governing code for exit items which are not covered in the regulations.