410 Ind. Admin. Code 7-24-222

Current through November 6, 2024
Section 410 IAC 7-24-222 - Equipment openings, closures, and deflectors

Authority: IC 16-42-5-5

Affected: IC 16-42-5

Sec. 222.

(a) A cover or lid for equipment shall overlap the opening and be sloped to drain.
(b) An opening located within the top of a unit of equipment that is designed for use with a cover or lid shall be flanged upward at least two-tenths (.2) of an inch.
(c) Except as specified under subsection (d):
(1) fixed piping;
(2) temperature measuring devices;
(3) rotary shafts; and
(4) other parts extending into equipment;

shall be provided with a watertight joint at the point where the item enters the equipment.

(d) If a watertight joint is not provided:
(1) the piping, temperature measuring devices, rotary shafts, and other parts extending through the openings shall be equipped with an apron designed to deflect condensation, drips, and dust from openings into the food; and
(2) the opening shall be flanged as specified in subsection (b).
(e) For purposes of this section, a violation of subsection (a), (b), (c), or (d) is a noncritical item.

410 IAC 7-24-222

Indiana State Department of Health; 410 IAC 7-24-222; filed Oct 13, 2004, 12:30 p.m.: 28 IR 865; readopted filed Jul 15, 2010, 12:12 p.m.: 20100728-IR-410100261RFA
Readopted filed 11/10/2016, 8:45 a.m.: 20161207-IR-410160371RFA
Readopted filed 9/15/2022, 10:01 a.m.: 20221012-IR-410220206RFA