410 Ind. Admin. Code 6-2.1-7.5

Current through November 6, 2024
Section 410 IAC 6-2.1-7.5 - "Maximum bather load" defined

Authority: IC 16-19-3-4

Affected: IC 16-19-3

Sec. 7.5.

"Maximum bather load" means the maximum usage of the pool calculated based on the following, whichever is applicable:

Shallow or wading areas (A) Deep areas, not including diving areas (B) Diving areas (per board) (C)
If the deck is less than the surface area of the pool 15 sq. ft. of pool surface area per bather 20 sq. ft. of pool surface per bather 300 sq. ft. of pool surface area per bather
If the deck is equal to or larger than the surface area of the pool 12 sq. ft. of pool surface area per bather 15 sq. ft. of pool surface per bather 300 sq. ft. of pool surface per bather
If the deck is twice the surface area of the pool 8 sq. ft. of pool surface per bather 10 sq. ft. of pool surface per bather 300 sq. ft. of pool surface area per bather

A+B+C= Maximum bather load. If the diving board(s) is closed, an additional 10 bathers are permitted.

410 IAC 6-2.1-7.5

Indiana State Department of Health; 410 IAC 6-2.1-7.5; filed Jul 26, 2010, 2:16 p.m.: 20100825-IR-410090006FRA
Readopted filed 9/30/2015, 2:45 p.m.: 20151028-IR-410150169RFA
Readopted filed 11/12/2021, 8:42 a.m.: 20211208-IR-410210386RFA