Authority: IC 16-19-3-4; IC 16-19-3-5
Affected: IC 16-19-3-4
Sec. 62.
Table III - Minimum Dispersal Areas for Soil Absorption Systems1 | |
Slope [LESS THAN] 1/2 %2: On-site sewage system without perimeter drain | One-fourth (1/4) width of soil absorption system5 |
Slope > 1/2 %3: On-site sewage system without perimeter drain | One-half (1/2) width of soil absorption system5 |
Any slope: On-site sewage system with perimeter drain4 | Ten (10) feet or the distance to the perimeter drain |
1No buildings, foundations, slabs, garages, patios, barns, aboveground and belowground swimming pools, retaining walls, roads, driveways, parking areas, or paved sidewalks are allowed in the dispersal area. | |
2Dispersal area is located on each side of the outside edge of the outer trench parallel to the length of the trench, or on each side of the outside edge of the sand area and parallel to the long axis of an elevated sand mound. | |
3Dispersal area is located on the downslope side of the soil absorption system. | |
4For on-site sewage systems with a subsurface perimeter drain without a seasonal high water table, the design and construction of the drain shall meet the requirements of section 63 of this rule. | |
5Dispersal area width shall not be less than ten (10) feet. A dispersal area width of more than twenty-five (25) feet is not required. |
410 IAC 6-10.1-62