Current through November 6, 2024
Section 410 IAC 6-10.1-20 - "High strength waste" definedAuthority: IC 16-19-3-4; IC 16-19-3-5
Affected: IC 16-19-3-4
Sec. 20.
"High strength waste" means either of the following as defined by National Sanitation Foundation International (NSF) Standard 40 testing protocol:
(1) Influent to a septic tank or other pretreatment component having any or all of the following: (A) A five (5) day biochemical demand (BOD5) greater than three hundred (300) mg/L.(B) Total suspended solids (TSS) greater than two hundred (200) mg/L.(C) Fats, oils, and grease (FOGs) greater than fifty (50) mg/L.(2) Effluent from a septic tank or other pretreatment component discharged to a soil absorption field having any or all of the following: (A) A BOD5 greater than one hundred seventy (170) mg/L.(B) TSS greater than sixty (60) mg/L.(C) FOGs greater than twenty-five (25) mg/L.Indiana State Department of Health; 410 IAC 6-10.1-20; filed Oct 19, 2012, 2:07 p.m.: 20121114-IR-410120157FRAReadopted filed 9/26/2018, 2:48 p.m.: 20181024-IR-410180328RFA