Haw. Code R. § 12-220-8.1

Current through August, 2024
Section 12-220-8.1 - Repairs and alterations
(a) Repairs, routine repairs, and alterations to pressure retaining items shall be in accordance with the requirements of the NBIC, Part 3, and this part. Applications for authorization for routine repair, repair, or alteration shall be submitted in the prescribed form and must be accompanied by the remittance of the appropriate fee for each pressure retaining item subject to this part as per the schedule in Exhibit A, titled, "Installation, Repair or Alteration Permit Fees, and Licensure, Examination, and Registration Fees", dated September 1, 2019, which is made part of this chapter and located at the end of this chapter, and inspection fee for each pressure retaining item subject to this part as per the schedule in Exhibit B, titled, "Internal & External Inspection Fees", dated September 1, 2019, which is made a part of this chapter and located at the end of this chapter. The applicant shall submit all the required documents and remittance fees to the department prior to commencement of work. A complete application shall include the name of the applicant, address, telephone number, NB "R" certificate of authorization number and expiration date, AIA of record, and name of the commissioned repair inspector.
(b) No pressure retaining item subject to this part shall be repaired or altered in the State unless:
(1) For routine repairs, in addition to the requirements of subsection (a), a copy of the manufacturer's data report and all partial data reports shall be submitted along with a detailed description of the proposed routine repair, drawings or pictures, material specifications, and a copy of the traveler or routine repair procedure to be used;
(2) For repairs, in addition to the requirements of subsection (a), a copy of the manufacturer's data report and all partial data reports shall be submitted along with a detailed description of the proposed repair, drawings or pictures, design calculations (if available), material specifications, and a copy of the traveler or repair procedure to be used; and (3) For alterations, in addition to the requirements of subsection (a), a copy of the manufacturer's data report and all partial data reports' shall be submitted along with a detailed description of the proposed alteration, drawings or pictures, design calculations, material specifications, and a copy of the traveler or alteration procedure to be used, and when applicable, a new maximum allowable working pressure and temperature of the pressure retaining item.
(c) It shall be the responsibility of the holder of a National Board "R" certificate of authorization making the routine repair, repair, or alteration to have a valid inspection contract or agreement in force at all times with an AIA that employs qualified boiler inspectors in compliance with NB-263, RCI-1 Rules for Commissioned Inspectors, and this part.
(d) It shall be the responsibility of the holder of a NB "R" certificate of authorization making the routine repair, repair, or alteration to provide for inspection, documentation, and certification of the work. A fully executed National Board "R" form shall be submitted to the department within thirty (30) days following the completion of the routine repairs, repairs, or alterations. Drawings or pictures, design calculations, non-destructive examination records, and traveler and other pertinent documents shall be maintained by the NB "R" certificate holder for five (5) years. The inspection agency responsible for the in-service inspection of the boiler or pressure vessel shall have access to review the fully executed National Board "R" form and other pertinent documents.

Haw. Code R. § 12-220-8.1

[Am and comp 12/21/2019] (Auth: § 397-4) (Imp: § 397-4)