1 Colo. Code Regs. § 212-3-3-220

Current through Register Vol. 47, No. 11, June 10, 2024
Section 1 CCR 212-3-3-220 - Security Alarm Systems and Lock Standards
A.Security Alarm Systems- Minimum Requirements. The following Security Alarm Systems and lock standards apply to all Regulated Marijuana Businesses, unless stated otherwise by these rules.
1. Each Licensed Premises shall have a Security Alarm System, installed by an Alarm Installation Company, on all perimeter entry points and perimeter windows.
2. Each Licensee must ensure that all of its Licensed Premises are continuously monitored. Licensees may engage the services of a Monitoring Company to fulfill this requirement.
3. A Licensee shall maintain up-to-date and current records and existing contracts on the Licensed Premises that describe the location and operation of each Security Alarm System, a schematic of security zones, the name of the Alarm Installation Company, and the name of any Monitoring Company. See Rule 3-905- Business Records Required.
4. Upon request, Licensees shall make available to agents of the Division or relevant Local Licensing Authority or Local Jurisdiction or state or local law enforcement agency, for a purpose authorized by the Marijuana Code or for any other state or local law enforcement purpose, all information related to Security Alarm Systems, Monitoring, and alarm activity.
5. Any outdoor or Greenhouse Medical Marijuana Cultivation Facility or Retail Marijuana Cultivation Facility is a Limited Access Area and must meet all of the requirements for Security Alarm Systems described in this Rule. An outdoor or Greenhouse Medical Marijuana Cultivation Facility or Retail Marijuana Cultivation Facility must provide sufficient security measures to demonstrate that outdoor areas are not readily accessible by unauthorized individuals. It shall be the responsibility of the Licensee to maintain physical security in a manner similar to a Medical Marijuana Cultivation Facility or Retail Marijuana Cultivation Facility located in an indoor Limited Access Area so it can be fully secured and alarmed. The fencing requirements shall include, at a minimum, perimeter fencing designed to prevent the general public from entering the Limited Access Areas and shall meet at least the following minimum requirements:
a. The entire Limited Access Area shall be surrounded by a fence constructed of nine gauge or lower metal chain link fence or another similarly secure material. The fence shall measure at least eight feet from the ground to the top, or in the alternative, the fence may measure six feet from the ground to the top with a 1 foot barbed wire arm with at least three strands along the entire fence. All support posts shall be steel and securely anchored.
b. All gates of ingress or egress shall measure at least eight feet from the ground to the top of the entry gate, or in the alternative, the gate may measure six feet from the ground to the top with a 1 foot barbed wire arm with at least three strands, and shall be constructed of nine gauge or lower metal chain link fence or a similarly secure material.
c. Repealed.
d. All areas of ingress and egress of the fence shall either:
i. Be illuminated including a 20 foot radius from the point of ingress or egress. Lights may be, but are not required to be, motion sensing; or
ii. Have cameras with night vision capacity capable of recording a 20 foot radius from the point of ingress or egress.
e. A Licensee or Applicant for initial licensure may, in writing, request that the Division waive one or more of the security requirements described in these subparagraphs (a) through (d) of this Rule, by submitting on a form prescribed by the Division a security waiver request for Division approval. The Division may, in its discretion and on a case-by-case basis, approve the security waiver if it finds that the alternative safeguard proposed by the Licensee or Applicant for initial licensure meets the goals of the above security requirements or that the security requirements are in conflict with a local ordinance of general applicability. Approved security waivers expire at the same time as the underlying License and may be renewed at the time the License renewal application is submitted. The Licensee's or Applicant for initial licensure's request for a waiver shall include:
i. The specific rules and subsections of a rule that are requested to be waived;
ii. The reason for the waiver;
iii. A description of an alternative safeguard the Licensee will implement in lieu of the requirement that is the subject of the waiver; and
iv. An explanation of how and why the alternative safeguard accomplishes the goals of the security rules, specifically public safety, prevention of diversion, accountability, and prohibiting access to minors.
B.Lock Standards- Minimum Requirement.
1. At all points of ingress and egress, the Licensee shall ensure the use of commercial-grade, non-residential door locks.
2. Any outdoor or Greenhouse Medical Marijuana Cultivation Facility or Retail Marijuana Cultivation Facility must meet all of the requirements for the lock standards described in this Rule.

Basis and Purpose - 3-225

The statutory authority for this rule includes but is not limited to sections 44-10-203(2)(h), 44-10-203(1)(k), 44-10-203(2)(e), 44-10-313(14), and 44-10-1001, C.R.S. Authority also exists in the Colorado Constitution at Article XVIII, Subsection 16(5)(a)(VI). The purpose of this rule is to ensure adequate control of the Licensed Premises and Regulated Marijuana contained therein. This rule also establishes the minimum guidelines for security requirements for video surveillance systems for maintaining adequate security. This Rule 3-225 was previously Rules M and R 306, 1 CCR 212-1 and 1 CCR 212-2.

1 CCR 212-3-3-220

42 CR 23, December 10, 2019, effective 1/1/2020
43 CR 21, November 10, 2020, effective 1/1/2021
44 CR 07, April 10, 2021, effective 5/1/2021
44 CR 13, July 10, 2021, effective 8/1/2021
44 CR 23, December 10, 2021, effective 1/1/2022
45 CR 21, November 10, 2022, effective 12/1/2022