Equipment class1 | Maximum PEI2 | C-value3 |
ESCC.1800.CL | 1.00 | 128.47 |
ESCC.3600.CL | 1.00 | 130.42 |
ESCC.1800.VL | 1.00 | 128.47 |
ESCC.3600.VL | 1.00 | 130.42 |
ESFM.1800.CL | 1.00 | 128.85 |
ESFM.3600.CL | 1.00 | 130.99 |
ESFM.1800.VL | 1.00 | 128.85 |
ESFM.3600.VL | 1.00 | 130.99 |
IL.1800.CL | 1.00 | 129.30 |
IL.3600.CL | 1.00 | 133.84 |
IL.1800.VL | 1.00 | 129.30 |
IL.3600.VL | 1.00 | 133.84 |
RSV.1800.CL | 1.00 | 129.63 |
RSV.3600.CL | 1.00 | 133.20 |
RSV.1800.VL | 1.00 | 129.63 |
RSV.3600.VL | 1.00 | 133.20 |
ST.1800.CL | 1.00 | 138.78 |
ST.3600.CL | 1.00 | 134.85 |
ST.1800.VL | 1.00 | 138.78 |
ST.3600.VL | 1.00 | 134.85 |
1 Equipment class designations consist of a combination (in sequential order separated by periods) of: (1) An equipment family (ESCC = end suction close-coupled, ESFM = end suction frame mounted/own bearing, IL = in-line, RSV = radially split, multi-stage, vertical, in-line diffuser casing, ST = submersible turbine; all as defined in § 431.462 ) ; (2) nominal speed of rotation (1800 = 1800 rpm, 3600 = 3600 rpm); and (3) an operating mode (CL = constant load, VL = variable load). Determination of the operating mode is determined using the test procedure in appendix A to this subpart.
2 For equipment classes ending in .CL, the relevant PEI is PEICL. For equipment classes ending in .VL, the relevant PEI is PEIVL.
3 The C-values shown in this table must be used in the equation for PERSTD when calculating PEICL or PEIVL, as described in section II.B of appendix A to this subpart.
Equipment class | Minimum allowable WEF score [kgal/kWh] | Minimum allowable WEF score [kgal/kWh] | |
Dedicated-purpose pool pump variety | hhp Applicability | Motor phase | |
Self-priming pool filter pumps | 0.711 hp [LESS THAN EQUAL TO]hhp [LESS THAN]2.5 hp | Single | WEF = -2.30 * ln (hhp) + 6.59. |
Self-priming pool filter pumps | hhp [LESS THAN]0.711 hp | Single | WEF = 5.55, for hhp [LESS THAN EQUAL TO]0.13 hp -1.30 * ln (hhp) + 2.90, for hhp [GREATER THAN]0.13 hp. |
Non-self-priming pool filter pumps | hhp [LESS THAN]2.5 hp | Any | WEF = 4.60, for hhp [LESS THAN EQUAL TO]0.13 hp -0.85 * ln (hhp) + 2.87, for hhp [GREATER THAN]0.13 hp. |
Pressure cleaner booster pumps | Any | Any | WEF = 0.42. |
EQUATION 1 TO PARAGRAPH (I)(3)(I)
Where:
CEI = the circulator energy index (dimensionless);
CER = the circulator energy rating (hp), determined in accordance with section 6 of appendix D to subpart Y of part 431; and
CERSTD = the CER for a circulator pump that is minimally compliant with DOE's energy conservation standards with the same hydraulic horsepower as the rated pump (hp), determined in accordance with paragraph (i)(3)(ii) of this section.
EQUATION 2 TO PARAGRAPH (I)(3)(II)
Where:
CERSTD = the CER for a circulator pump that is minimally compliant with DOE's energy conservation standards with the same hydraulic horsepower as the rated pump (hp);
i = the index variable of the summation notation used to express CERSTD (dimensionless) as described in the table 3 to paragraph (i)(3)(ii), in which i is expressed as a percentage of circulator pump flow at best efficiency point, determined in accordance with the test procedure in § 431.464(c)(2) ;
[OMEGA]i = the weighting factor (dimensionless) at each corresponding test point, i, as described in table 3 to paragraph (i)(3)(ii); and Piin,STD = the reference power input to the circulator pump driver (hp) at test point i, calculated using the equations and method specified in paragraph (i)(3)(iii) of this section.
Table 3 to Paragraph (i)(3)(ii)
I (%) | Corresponding [OMEGA]i |
25 | .25 |
50 | .25 |
75 | .25 |
100 | .25 |
EQUATION 3 TO PARAGRAPH (I)(3)(III)
Where:
Piin,STD = the reference power input to the circulator pump driver at test point i (hp);
Pu,i = circulator pump basic model rated hydraulic horsepower (hp) determined in accordance with 10 CFR 429.59(a)(2)(i) ;
[ALPHA]i = part-load efficiency factor (dimensionless) at each test point i as described in table 4 to paragraph (i)(3)(iii); and
[ETA]WTW,100% = reference circulator pump wire-to-water efficiency at best efficiency point (%) at the applicable energy conservation standard level, as described in table 5 to paragraph (i)(3)(iii) as a function of circulator pump basic model rated hydraulic horsepower at 100% BEP flow, Pu,100% .
Table 4 to Paragraph (i)(3)(iii)
I (%) | Corresponding [ALPHA]i |
25 | 0.4843 |
50 | 0.7736 |
75 | 0.9417 |
100 | 1 |
Table 5 to Paragraph ( i )(3)(iii)
Pu,100% | [ETA]WTW,100% |
<1 | 10*ln(Pu,100% + 0.001141) + 67.78. |
[GREATER THAN EQUAL TO]1 | 67.79%. |
10 C.F.R. §431.465