49 C.F.R. § 192.113

Current through March 31, 2024
Section 192.113 - Longitudinal joint factor ( E ) for steel pipe

The longitudinal joint factor to be used in the design formula in §192.105 is determined in accordance with the following table:

SpecificationPipe classLongitudinal joint factor (E)
ASTM A 53/A53MSeamless1.00
Electric resistance welded1.00
Furnace butt welded.60
ASTM A 106Seamless1.00
ASTM A 333/A 333MSeamless1.00
Electric resistance welded1.00
ASTM A 381Double submerged arc welded1.00
ASTM A 671Electric-fusion-welded1.00
ASTM A 672Electric-fusion-welded1.00
ASTM A 691Electric-fusion-welded1.00
API 5 LSeamless1.00
Electric resistance welded1.00
Electric flash welded1.00
Submerged arc welded1.00
Furnace butt welded.60
OtherPipe over 4 inches (102 millimeters).80
OtherPipe 4 inches (102 millimeters) or less.60

If the type of longitudinal joint cannot be determined, the joint factor to be used must not exceed that designated for "Other."

49 C.F.R. §192.113

Amdt. 192-37, 46 FR 10159, 2/2/1981, as amended by Amdt. 192-51, 51 FR 15335, 4/23/1986; Amdt. 192-62, 54 FR 5627, 2/6/1989; 58 FR 14521, 3/18/1993; Amdt. 192-85, 63 FR 37502, 7/13/1998; Amdt. 192-94, 69 FR 32894, 6/14/2004