N.Y. Comp. Codes R. & Regs. tit. 10 § 59.4

Current through Register Vol. 46, No. 16, April 17, 2024
Section 59.4 - Breath analysis instruments
(a) The commissioner approves, for use in New York State, breath analysis instruments found on the Conforming Products List of Evidential Breath Alcohol Measurement Devices as established by the U.S. Department of Transportation/National Highway Traffic Safety Administration (NHTSA), published in the Federal Register on March 11, 2010 (75 Fed. Reg. 11624-11627, available for public inspection and copying at the Department of Health Records Access Office, Corning Tower, Empire State Plaza, Albany, NY 12237). A facsimile of that list is set forth in subdivision (b) of this section. At the request of a training agency, the commissioner may approve a breath analysis instrument that has been accepted by NHTSA but is not on the Conforming Products List published in the Federal Register on March 11, 2010, if the commissioner determines that approval of such instrument is appropriate.
(b)Conforming Products List of Evidential Breath Measurement Devices.

Federal Register / Vol. 75, No. 47 / Thursday, March 11, 2010 / Notices

CONFORMING PRODUCTS LIST OF EVIDENTIAL BREATH MEASUREMENT DEVICES

Manufacturer and modelMobileNonmobile
Alcohol Countermeasure Systems Corp., Mississauga, Ontario, Canada:
Alert J3AD*XX
Alert J4X.ecXX
PBA3000CXX
BAC Systems, Inc., Ontario, Canada
Breath Analysis Computer*XX
CAMEC Ltd., North Shields, Tyne and Ware, England:
IR Breath Analyzer*XX
CMI, Inc., Owensboro, Kentucky:
Intoxilyzer Model:
200XX
200DXX
240 (aka: Lion Alcolmeter 400+ outside the U.S.)XX
300XX
400XX
400PAXX
1400XX
4011*XX
4011A*XX
4011AS*XX
4011AS-A*XX
4011AS-AQ*XX
4011AW*XX
4011A27-10100*XX
4011A27-10100 with filter*XX
5000XX
5000 (w/Cal. Vapor Re-Circ.)XX
5000 (w/3/8" ID Hose option)XX
5000CDXX
5000CD/FG5XX
5000ENXX
5000 (CAL DOJ)XX
5000VAXX
8000XX
PAC 1200*XX
S-D2XX
S-D5 (aka: Lion Alcolmeter SD-5 outside the U.S.)XX
Draeger Safety, Inc. (aka: National Draeger) Irving, Texas:
Alcotest Model:
6510XX
6810XX
7010*XX
7110*XX
7110 MKIIIXX
7110 MKIII-CXX
7410XX
7410 PlusXX
7510XX
9510XX
Breathalyzer Model:
900XX
900A*XX
900BG*XX
7410XX
7410-IIXX
EnviteC by Honeywell GmbH, Fond du Lac, Wisconsin:
AlcoQuant 6020XX
Gall's Inc., Lexington, Kentucky:
Alcohol Detection System-A.D.S. 500XX
Guth Laboratories, Inc., Harrisburg, Pennsylvania:
Alcotector BAC-100XX
Alcotector C2H5OHXX
Intoximeters, Inc., St. Louis, Missouri:
Photo Electric Intoximeter*X
GC Intoximeter MK II*XX
GC Intoximeter MK IV*XX
Auto Intoximeter*XX
Intoximeter Model:
3000XX
3000 (rev B1)*XX
3000 (rev B2)*XX
3000 (rev B2A)*XX
3000 (rev B2A) w/FM option*XX
3000 (Fuel Cell)*XX
3000 D*XX
3000 DFC*XX
AlcomonitorX
Alcomonitor CCXX
Alco-Sensor IIIXX
Alco-Sensor III (Enhanced with Serial Numbers above 1,200,000)XX
Alco-Sensor IVXX
Alco-Sensor IV XLXX
Alco-Sensor VXX
Alco-Sensor AZXX
Alco-Sensor FSTXX
Intox EC/IRXX
Intox EC/IR IIXX
Intox EC/IR II (Enhanced with serial number 10,000 or higher)X
Portable Intox EC/IRXX
RBT-AZXX
RBT-IIIXX
RBT III-AXX
RBT IVXX
RBT IV with CEM (cell enhancement module)XX
Komyo Kitagawa, Kogyo, K.K., Japan:
Alcolyzer DPA-2*XX
Breath Alcohol Meter PAM 101B *XX
Lifeloc Technologies, Inc., (formerly Lifeloc, Inc.), Wheat Ridge, Colorado:
PBA 3000BXX
PBA 3000-P *XX
PBA 3000CXX
Alcohol Data SensorXX
PhoenixXX
Phoenix 6.0XX
EV 30XX
FC 10XX
FC 20XX
Lion Laboratories, Ltd., Cardiff, Wales, United Kingdom:
Alcolmeter Model:
300XX
400XX
400+ (aka: Intoxilyzer 240 in the U.S.)XX
SD-2 *XX
SD-5 (aka: S-D5 in the U.S.)XX
EBA*XX
Intoxilyzer Model:
200XX
200DXX
1400XX
5000 CD/FG5XX
5000 ENXX
Luckey Laboratories, San Bernardino, California:
Alco-Analyzer Model:
1000*X
2000*X
Nanopuls AB, Uppsala, Sweden:
EvidenzerXX
National Patent Analytical Systems, Inc., Mansfield, Ohio:
BAC DataMaster (with or without the Delta-1 accessory):
BAC Verifier DataMaster (w/or without the Delta-1 accessory)XX
DataMaster cdm (w/or without the Delta-1 accessory)XX
DataMaster DMTXX
Omicron Systems, Palo Alto, California:
Intoxilyzer Model:
4011*XX
4011AW *XX
PAS International, Fredericksburg, Virginia:
Mark V AlcovisorXX
Plus 4 Engineering, Minturn, Colorado:
5000 Plus 4*XX
Seres, Paris, France:
Alco MasterXX
AlcoproXX
Siemans-Allis, Cherry Hill, New Jersey:
Alcomat*XX
Alcomat F*XX
Smith and Wesson Electronics, Springfield, Massachusetts:
Breathalyzer Model:
900*XX
900A*XX
1000*XX
2000*XX
2000 (non-Humidity Sensor)*XX
Sound-Off, Inc., Hudsonville, Michigan:
AlcoDataXX
Seres Alco MasterXX
Seres AlcoproXX
Stephenson Corp.:
Breathalyzer 900*XX
Tokai-Denshi Inc., Tokyo, Japan:
ALC-PRO II (US)XX
U.S. Alcohol Testing, Inc./Protection Devices, Inc., Rancho Cucamonga, California:
Alco-Analyzer 1000X
Alco-Analyzer 2000X
Alco-Analyzer 2100XX
Verax Systems, Inc., Fairport, New York:
BAC Verifier*XX
BAC Verifier DatamasterXX
BAC Verifier Datamaster II*XX

_______

* Instruments marked with an asterisk (*) meet the Model Specifications detailed in 49 FR 48854 (December 14, 1984) (i.e., instruments tested at 0.000, 0.050, 0.101, and 0.151 BAC.) Instruments not marked with an asterisk meet the Model Specifications detailed in 58 FR 48705 (September 17, 1993), and were tested at BACs = 0.000, 0.020, 0.040, 0.080, and 0.160. All instruments that meet the Model Specifications currently in effect (dated September 17, 1993) also meet the Model Specifications for Screening Devices to Measure Alcohol in Bodily Fluids.

(c) No law enforcement agency shall use a breath analysis instrument unless the training agency has verified that representative samples of the specific make and model perform properly. Maintenance shall be conducted as specified by the training agency, and shall include, but shall not be limited to, calibration at a frequency as recommended by the device manufacturer or, minimally, annually.
(d) Training agencies shall be responsible for maintaining records pertaining to verification and maintenance (including calibration) of breath analysis instruments and standards; provided, however, that record keeping maintenance may be delegated, in whole or in part, to the law enforcement agency using the breath analysis instrument(s).

N.Y. Comp. Codes R. & Regs. Tit. 10 § 59.4