Subsection 1109.12 - Controls, operating mechanisms and hardware Controls, operating mechanisms and hardware intended for operation by the occupant, including switches that control lighting and ventilation and electrical convenience outlets, in accessible spaces, along accessible routes or as parts of accessible elements shall be accessible.
Exceptions:
1. Operable parts that are intended for use only by service or maintenance personnel shall not be required to be accessible.2. Electrical or communication receptacles serving a dedicated use shall not be required to be accessible.3. Where two or more outlets are provided in a kitchen above a length of counter top that is uninterrupted by a sink or appliance, one outlet shall not be required to be accessible.4. Floor electrical receptacles shall not be required to be accessible.5. HVAC diffusers shall not be required to be accessible.6. Except for light switches, where redundant controls are provided for a single element, one control in each space shall not be required to be accessible.7. Access doors or gates in barrier walls and fences protecting pools, spas and hot tubs shall be permitted to have operable parts of the release of latch on self-latching devices at 54 inches (1370 mm) maximum and 48 inches (1219 mm) minimum above the finished floor or ground, provided the self-latching devices are not also self-locking devices, operated by means of a key, electronic opener, or integral combination lock. 1109.12.1Operable window. Where operable windows are provided in rooms that are required to be accessible in accordance with Sections 1107.5.1.1, 1107.5.2.1, 1107.5.3.1, 1107.5.4, 1107.6.1.1, 1107.6.2.1.1, 1107.6.2.2.1 and 1107.6.4.1, at least one window in each room shall be accessible and each required operable window shall be accessible. Exception: Accessible windows are not required in bathrooms and kitchens.